Autoclave SK07

  • Dental autoclave class b Sk07
    Easy to use, low maintenance: the autoclave in its best shape
    The SK07 class B Autoclave version 16 and 21 is the vanguard of the dental sterilization sector for which FARO’s Research and Development department has accurately selected its new composition, using electronics of the latest generation produced with SMT technology. This technology allows to minimize energy and water consumption and requires very little maintenance. The design is sober and ultra-modern for a perfect integration in the dental clinic, increasing its overall aesthetic quality.
     
    SK07 AUTOCLAVE 
    VERSIONs 16 and 21
    INTEGRATED PRINTER
    the printing or data storage devices 
    are housed inside the lower door.
     
    SK07 AUTOCLAVE 
    VERSIONs 16 and 21
    COMPACT FLASH
    Memory card type: Compact Flash
    record the cycles by means of the
    pecific SK07 Agent Compact Flash software supplied.
     
    SK07 AUTOCLAVE 
    VERSIONs 16 and 21
    EXTERNAL PRINTER
    with a connection to an external printer which allows coupon printing with detailed information about each cycle. 
     
    Dental autoclave class b Sk07 Dental autoclave class b Sk07 Dental autoclave class b Sk07
     
    Specifications
    • Performs B-type cycles (121°C - 134°C - 134°C B-Flash - 134°C Prion) and test cycles: Bowie and Dick, Helix Test, Vacuum Test
    • B Flash Cycle while respecting the parameters required, can reduce the sterilization process time of the small loads (up to 0.5 kg - version 16 and up to 0.7 Kg - version 21)
    • LCD Display and user-friendly Control panel with 4 buttons to visualize instructions and information.
    • Control of the physical cycle characteristics.
    • Integrated safety system to monitor every phase of the sterilization cycle and to inform the user about any possible failure.
    • Direct connection to the main water supply.
    • Quick coupling faucets to load the water tank and drain the draining tank rapidly.
    • Automatic load of the tank: all the autoclaves contain an internal tank to automatically charge the water and a tank for the used water.
    • Long autonomy: 10-12 cycles (version 16) or 7-8 cycles (version 21) with a single load of distilled water in the integrated tank.
    • Automatic loading of the tank by integrated water pump
    • Limited water consumption thanks to the water injection pump in the chamber, which is managed by a software that avoids any waste.
    • Low energy consumption: extremely low electricity consumption thanks to a copper chamber which has a better conduction capacity (compared to the ones in steel) and thanks to a resistance which is splitted in 3 software-managed sectors in order to avoid the heating where not necessary.
    • Automatic low-temperature Standby to reduce the preheating time saving energy.
    • Quick and easy porthole adjustment, by a simple pression on the button on the door and turning the porthole.
    • Maximum temperature uniformity: the temperature and the pressure remain steady inside the sterilization chamber.
    • “Last cycle” system: automatic advanced last cycle system, for a perfect dry of the loads.
  • GENERAL FEATURES*
    GENERAL SPECIFICATIONS  AUTOCLAVE SK07 – 16 LT  AUTOCLAVE SK07 – 21 LT
    Main voltage 230V - 50/60 Hz 230V - 50/60 Hz
    Max Power absorbed 7,5 A 9,8 A
    Max Current absorbed 1725 W 2270 W
    Average consumption per cycle
    (variable depending on the load and type of cycle)
    980 W
     
    1300 W
     
    Medical Device complies to the directive 93/42/EEC and s.m.i. - Medical devices - Applied standards: EN 13060 - Small steam sterilizers, EN 61326 Electrical equipment for measurement, control and laboratory, EMC requirements, EN 61010-1 - Safety requirements for electrical equipment for measurement, control and laboratory use General requirements, EN 61010-2-40 - Safety requirements for electrical equipment for measurement, particular requirements for sterilizers; 24-month-guarantee.

    VOLUMES AND CONSUMPTIONS  AUTOCLAVE SK07 – 16 LT  AUTOCLAVE SK07 – 21 LT
    Loading tank capacity 3,65 lt 3,65 lt
    Autonomy cycles with a single load of distilled water in the integrated tank 10-12
     
    7-8
     
    Distilled water consumption per cycle 220÷300 ml 260÷330 ml

    DIMENSIONS  AUTOCLAVE SK07 – 16 LT  AUTOCLAVE SK07 – 21 LT
    Chamber diameter 240 mm 240 mm
    Chamber length 360 mm 460 mm
    Minimum overall dimension of the housing 690 x 450 x 489 mm 790 x 450 x 489 mm
    Minimum depth of bench to place the autoclave 520 - 540 mm 580 - 600 mm
    Tray dimensions 285 x 184 mm 382 x 184 mm

    LOADS  AUTOCLAVE SK07 – 16 LT  AUTOCLAVE SK07 – 21 LT
    Max solid Load (wrapped) 2,0 Kg 3,5 Kg
    Max solid Load (unwrapped) 4,0 Kg 6,0 Kg
    Max Load (porous) 1,3 Kg 1,8 Kg
    Max solid Load for B FLASH fast cycle (wrapped) 0,5 Kg 0,7 Kg
    Max Load for B FLASH fast cycle (porous) 0,2 Kg 0,3 Kg

    STERILI ZATION CYCL ES 
    (times variable on the load introduced)
     AUTOCLAVE SK07 – 16 LT  AUTOCLAVE SK07 – 21 LT
    134°C - Standard cycle From 38’ to 43’ From 31’ to 37’
    134°C - Prion cycle From 52’ to 58’ From 45’ to 47’
    121°C - Standard cycle From 53’ to 56’ From 46’ to 48’
    134°C - B FLASH cycle From 26’ From 23’ to 25’

    EQUIPMENT  AUTOCLAVE SK07 – 16 LT  AUTOCLAVE SK07 – 21 LT
    Standard equipment 1 tray holder + 3 tray 1 tray holder + 3 tray
    Possibility to introduce surgical cassettes in the tray holder (rotating the support of 90°) Yes Yes
         
    *(The above specifications are typical values subject to tolerance)  
  • Weekly ordinary maintenance

    Chamber cleaning
    Clean the chamber and the door panel with a soft cloth by using a liquid solution (not creamy) for steel (normally available in the different supermarkets) duly diluted with water. During the cleaning procedure of chamber pay attention not to damage or modify the position of the temperature probe. At the end rinse out with water.
    Door cleaning
    Clean the door panel gasket with a soft cloth soaked in water and if necessary adjust the portole by pressing the pushbutton and rotating the porthole anticlockwise. Release the pushbutton and keep on rotating the porthole until it is completely locked off.
    Front panel cleaning
    Clean the front panel with a soft cloth soaked in alcohol. Pay attention not to let the alcohol penetrate inside the autoclave. Instead of alcohol it will be possibile to use any alternative liquid, containing ammonia, indicated for glasses. Do not use  products containing trichlorethylene, petrol, white spirit or solvents in general.
     
    Yearly ordinary maintenance or every 1000 cycles
    • Replace the bio-x filter.
    • Replace the porthole gasket.
    • Replace the water filter inside the chamber.
    • Call a specialized technician to drain and clean the filling tank.

#502, Barton Centre 84, MG Road, Bangalore +91-80-25591234 info@farodentalindia .com

About Us

FARO S.p.A., founded in 1948 by Osvaldo Favonio, designs and produces equipment for the manufacturer of dental units, dental cabinets and dental laboratories. In over 5,000 square meters of the production plant in Ornago (MB), both the production and the design and research & development take place. 

Newsletter

Enter your email to join our mailing list

Sales Services

The effort we put into sales services is thought to build solid, cordial, human relations. Reliable relations, so durable as our products are. We are at your side to keep you updated about the news, we help you to choose the right product by answering to your questions and providing all the documentation; we assist you in managing the orders and we answer to your questions about the use and maintenance of the equipments.